INDUSTRY SECTORS WE SERVE TO
This product is an electric immersion heater intended for use within a potentially hazardous areas where a risk for exposure to explosive gas atmosphere exist.
The heater must be horizontally mounted into a tank, vessel or a pipe-based flow through system, and the heating elements shall be totally immersed in liquid during operational use.
The heating elements submerged in liquid, is considered as a non-Ex area.
The immersion heater’s type designation is SIH KLXT…H/M/L-…Exd.
Its main parts are the electric heating elements brazed into a BSP G2” threaded bulb-head manufactured in stainless steel AISI316L, and Exd junction box made of cast aluminum.
The heater is controlled by automatically resettable thermostat that regulates the temperature and determines the T-class. Set-point must be agreed with manufacturer when placing order, and cannot be adjusted by end-user.
An additional manual resettable thermostat is mounted for the safety (TSHH). T-class for this equipment is based on the TSHH cut-off.
TSHH is preset and fixed at its set-point.
Supply voltages: |
1x230V/16A, 3x230V/30,2A, 3x400V/17,4A or 3x690V/10,1A |
Electrical power: |
Various steps from 0,75kW to 6kW as standard (see VARIANTS) |
Surface loads: |
H = Max 7W/cm². M = 2,5W/cm². L = 0,9W/cm² |
Immersion lengths: |
200mm to 1350mm depending on power and surface load (see VARIANTS) |
Mechanical connection: |
BSP G2” thread |
Cable glands: |
Exd certified M25 |
Ingress Protection: |
IP66 |
Operational temperature: |
Max 90 °C |
T-class: |
T4 (max 135 °C surface temp). |
Ambient temperature: |
-30 °C to +60 °C. |
Working pressure: |
Max 10 bar (145 lbs.) |
EX marking: |
ATEX: CE0470
IECEx: Ex db IIC T4 Gb |
Ex certificates: |
Presafe 19 ATEX 0712X and IECEx PRE 19.0062X |
Intended for use in liquid with high thermal capacity (water, glycol etc).
Type: |
Power: |
Voltage (specify by order): |
Surface load (max): |
Immersion length: |
SIH KLXT 1,0H-…Exd |
1,0kW |
230, 400 or 690V |
7W/cm² |
200mm |
SIH KLXT 1,5H-…Exd |
1,5kW |
230, 400 or 690V |
7W/cm² |
210mm |
SIH KLXT 2,0H-…Exd |
2,0kW |
230, 400 or 690V |
7W/cm² |
230mm |
SIH KLXT 2,5H-…Exd |
2,5kW |
230, 400 or 690V |
7W/cm² |
285mm |
SIH KLXT 3,0H-…Exd |
3,0kW |
230, 400 or 690V |
7W/cm² |
300mm |
SIH KLXT 3,5H-…Exd |
3,5kW |
230, 400 or 690V |
7W/cm² |
315mm |
SIH KLXT 4,0H-…Exd |
4,0kW |
230, 400 or 690V |
7W/cm² |
330mm |
SIH KLXT 4,5H-…Exd |
4,5kW |
230, 400 or 690V |
7W/cm² |
350mm |
SIH KLXT 5,0H-…Exd |
5,0kW |
230, 400 or 690V |
7W/cm² |
370mm |
SIH KLXT 5,5H-…Exd |
5,5kW |
230, 400 or 690V |
7W/cm² |
390mm |
SIH KLXT 6,0H-…Exd |
6,0kW |
230, 400 or 690V |
7W/cm² |
410mm |
Intended for use in liquid with a lower thermal capacity (light oils, gasol, vegetable oils etc.)
Type: |
Power: |
Voltage (specify by order): |
Surface load (max): |
Immersion length: |
SIH KLXT 1,0M-…Exd |
1,0kW |
230, 400 or 690V |
2,5W/cm² |
300mm |
SIH KLXT 2,0M-…Exd |
2,0kW |
230, 400 or 690V |
2,5W/cm² |
400mm |
SIH KLXT 3,0M-…Exd |
3,0kW |
230, 400 or 690V |
2,5W/cm² |
550mm |
SIH KLXT 4,0M-…Exd |
4,0kW |
230, 400 or 690V |
2,5W/cm² |
700mm |
SIH KLXT 5,0M-…Exd |
5,0kW |
230, 400 or 690V |
2,5W/cm² |
850mm |
SIH KLXT 6,0M-…Exd |
6,0kW |
230, 400 or 690V |
2,5W/cm² |
1000mm |
Intended for use in liquid with low thermal capacities (heavy oil, tar, some chemical baths etc.)
Type: |
Power: |
Voltage (specify by order): |
Surface load (max): |
Immersion length: |
SIH KLXT 0,75L-…Exd |
0,75kW |
230, 400 or 690V |
0,9W/cm² |
400mm |
SIH KLXT 1,0L-…Exd |
1,0kW |
230, 400 or 690V |
0,9W/cm² |
500mm |
SIH KLXT 1,5L-…Exd |
1,5kW |
230, 400 or 690V |
0,9W/cm² |
700mm |
SIH KLXT 2,0L-…Exd |
2,0kW |
230, 400 or 690V |
0,9W/cm² |
900mm |
SIH KLXT 2,5L-…Exd |
2,5kW |
230, 400 or 690V |
0,9W/cm² |
1100mm |
SIH KLXT 3,0L-…Exd |
3,0kW |
230, 400 or 690V |
0,9W/cm² |
1350mm |
To ensure a proper mounting of the SIH KLXT…. heater, we recommend you to order thespecial tools “Hylsnyckel SW75” and the “Backer SW92 spanner” in addition to the heater.
The heaters are delivered with a following technical file - containing an installation manual, a brief description of the heater’s manner of operation. Information about maintenance, transport handling, lifting and storage.
In the technical file also the Ex certificates and our declaration of conformity (DoC) can be found.
NORSKE BACKER AS · JOSTEIN SVENHEIMS VEG 8-10 · NO-2212 KONGSVINGER · TEL. +4762828828
SALG/FORESPØRSEL: [email protected] · FAKTURAADRESSE: [email protected]